Unable to run application from Application Manager
Technical Note USA10721Created 22-Jun-2004Applies To
KEA! X 6.0
Symptoms
Unable to run application from Application ManagerError: "Cannot open display"PING and nslookup of IP addresses return correct and consistent DNS informationFirewallDNS
Cause
The Firewall port was blocked, didn't allow X-traffic to go through
Fix
Make sure that ports 6000 and above (6001, 6002 depending which display number is being used) are enabled so that the X-traffic can get through.
For related information see solutions USA3747 and 1.0.1557880.3039398